[DW-VG4] CODE=702 occurred during the weekend

Description

DW-VG412 & DW-VG416

v1.5.4.2


We set our recording mode to Continous and left for the weekend.

My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.)

What is the meaning of the Internal check code that occurred before the reboot?

David’s DW-VG416

DW-VG412

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity

Brandon Krebs updated the Component at 24 July 2024, 16:49
None → VMAX IP G4
Gayoung Nam changed the Priority at 21 August 2023, 23:27
Medium → Highest
Brandon Krebs updated the Resolution at 15 August 2023, 15:25
None → Done
Brandon Krebs changed the Status at 15 August 2023, 15:25
In Review → Done
FOCUS_JH changed the Status at 7 August 2023, 07:36
To Do → In Review
Brandon Krebs updated the Description at 31 July 2023, 22:22
DW-VG412 & DW-VG416 v1.5.4.2 ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! DW-VG412 !image-20230731-212337.png|width=1235,height=498! → *DW-VG412 & DW-VG416* *v1.5.4.2* ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! DW-VG412 !image-20230731-212337.png|width=1235,height=498!
Brandon Krebs updated the Description at 31 July 2023, 22:03
DW-VG412 & DW-VG416 v1.5.4.2 ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! David’s Camera Log !image-20230731-215629.png|width=475,height=259! DW-VG412 !image-20230731-212337.png|width=1235,height=498! → DW-VG412 & DW-VG416 v1.5.4.2 ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! DW-VG412 !image-20230731-212337.png|width=1235,height=498!
Brandon Krebs updated the Description at 31 July 2023, 21:56
DW-VG412 & DW-VG416 v1.5.4.2 ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! David’s Camera Log DW-VG412 !image-20230731-212337.png|width=1235,height=498! → DW-VG412 & DW-VG416 v1.5.4.2 ---- We set our recording mode to Continous and left for the weekend. My 12CH and David’s 16CH had the error code=702. (Screenshot of the logs are below.) {panel:bgColor=#eae6ff} What is the meaning of the Internal check code that occurred before the reboot? {panel} David’s DW-VG416 !image-20230731-212418.png|width=50%! David’s Camera Log !image-20230731-215629.png|width=475,height=259! DW-VG412 !image-20230731-212337.png|width=1235,height=498!
Unknown User created the Issue at 31 July 2023, 21:56