[DW-VG4] Incorrect notification when trying to delete embedded cameras on the web.
Description
TEST PF Site & smartwebviewer
DW-VG4
Version 1.5.5.4
Deleting cameras from Testpf site and smartweb viewer shows success message but doesn't delete cameras.
-
Log in to Testpf site or smartweb viewer.
-
Navigate to the camera management.
-
Select a camera connected to an embedded POE switch Ex 1-4.
-
Attempt to delete the camera.
-
Observe the message stating "Successfully updated."
Expected Result:
Cameras connected to embedded POE switch should not be deletable unless there is video loss. Delete should be disabled like local side.
Actual Result:
Message indicates successful update, but camera remains undeleted.
Upload attachments
Drop your files to upload
(Max file size: 1.00 GiB)
Uploading...
(Template) Current File Name (1 / 7)
123KB / 2.1MB
(Template) File Name
123KB / 2.1MB
Upload completed. Click here to reload the page.
Child issues
Linked work items
Can’t link the work item VMAX-485 to itself.
Activity
Show:
Create issue
Add watchers
Details
Priority
Created: 17 July 2024, 18:16
Updated:
18 July 2024, 01:40
연결되어있는 PoE CH은 삭제가 불가능합니다. (Local 도 동일함.)
메세지 변경 이나, PoE CH 삭제 비활성화는 추후 수정하도록 하겠습니다.