[DW-VA1G4] Entering the password of user without shutdown permission when trying to reboot *Fixed*

Description

F/W v1.0.8.0

Model: DW-VA1G416xT

An user without Shutdown(Function) permission in User menu cannot reboot, shutdown.

So, If you click shutdown button and select a user who does not have shutdown permission to enter password, you cannot shutdown.

shutdown was fixed before but for Reboot it is still possible to reboot with selecting user without shutdown permission on the window of below image.

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity

Brandon Krebs updated the Fix Version at 24 February 2023, 17:38
None → v1.0.9.0 - VMAX A1 G4
Brandon Krebs updated the Resolution at 24 February 2023, 17:31
None → Done
Brandon Krebs changed the Status at 24 February 2023, 17:31
In Progress → Done
Brandon Krebs updated the Summary at 24 February 2023, 17:31
[DW-VA1G4] Entering the password of user without shutdown permission when trying to reboot → [DW-VA1G4] Entering the password of user without shutdown permission when trying to reboot *Fixed*
Brandon Krebs changed the Status at 15 February 2023, 17:59
In Review → In Progress
Gayoung Nam changed the Status at 26 January 2023, 16:12
To Do → In Review
Gayoung Nam updated the Summary at 25 January 2023, 17:30
[DW-VA1G416xT] Entering the password of user without shutdown permission when trying to reboot → [DW-VA1G4] Entering the password of user without shutdown permission when trying to reboot
Unknown User created the Issue at 25 January 2023, 17:14