[DW-VA1G4] Group recording sensor event does not record all channels. *Non-issue*

Description

F/W: v1.0.9.0

MODEL: DW-VA1G44xT


DEVICE > CAMERA > GROUP RECORDING Set all channels to group A. Connect a wire to the Alarm In #1 input and connect the other end to ground. The sensor icon appears only on CH1. Only playback CH1 has data.

The group recording functioned normally with motion. The group recording correctly changed all recording modes to sync with the other CHs