[DW-VG4]Emergency Record on Web Assembly needs improvement
Description
F/W: v1.5.3.2
Model: DW-VG49
On Chrome/Edge/Firefox, the Emergency Record mode is only visible for CH1. CH1 displays ‘Panic!’ within 1-3 mins and then disappears. On I.E all channels display ‘EMG’ and the alert remains until the Emergency Record mode is toggled off.
Please refer to the following screenshots for reference:
Local Side:
I.E.:
Chome:
Attachments
Upload attachments
Drop your files to upload
(Max file size: 1.00 GiB)
Uploading...
(Template) Current File Name (1 / 7)
123KB / 2.1MB
(Template) File Name
123KB / 2.1MB
Upload completed. Click here to reload the page.
Child issues
Linked work items
Can’t link the work item VMAX-23 to itself.
Activity
Show:
Create issue
Add watchers
Details
Priority
Created: 11 January 2023, 21:49
Updated:
30 March 2023, 23:21
fixed f/w v1.5.3.7 + 1.1.4.93
(DVR) FDR-3116 1.0.9.2 + SmartWebview 1.1.4.91
> 수정확인됨, (단, PANIC 실행전 직전 연속적인 이벤트가 발생했을 경우 해당 EVENT ICON 과 같이 표현됨)
Reproduced v1.5.3.6
Not fixed F/W v1.5.3.4