[DW-VG4]All Sensor recording modes on web assembly issue with the channel alert icon.

Description

F/W: v1.5.3.2

Model: DW-VG49


This issue was first discovered with Motion + Sensor mode. I continued testing to discover all Sensor related recording schedules are affected.

RECORD > SCHEDULE - When the recording schedule is set to Motion + Sensor on all 4 channels CH1 does not display the sensor alert icon. The local side does display the alert, but on Chrome, it does not. CH 2,3,4 all does have the icon. CH4 the icon disappears after 2-3 mins. CH 2,3 remains on until the alarm is changed.

Please view the video link for reference (The sensor is set to NC to keep detection on): https://screenrec.com/share/0OP8IxqQVd

Additional information: With Sensor mode scheduled on all 4 Channels. Only CH1 does not display the icon. CH 2,3,4 the alert remains until the alarm is changed. Please view the screenshot for reference:

With Continous + Sensor mode scheduled on all 4 Channels. Only CH1 does not display the icon. CH 2,3,4 the alert remains until the alarm is changed. Please view the screenshot for reference:

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity

Brandon Krebs 30 March 2023, 23:21

fixed f/w v1.5.3.7 + v1.1.4.93

FOCUS_JH 21 March 2023, 06:26

DW-VG416_v1.5.3.7(20230321) + SmartWebview 1.1.4.92 > 수정확인

Brandon Krebs 8 March 2023, 18:54

Reproduced v1.5.3.6

Brandon Krebs 31 January 2023, 21:44

Not fixed F/W v1.5.3.4

FOCUS_JH (jhjung@focushns.com) 12 January 2023, 06:36

(조건)
Sensor Event 가 연속 발생하는 상태에서 Schedule을 변경하다보면 증상 재현됨.
현상태에서 Sensor Event 를 중단했다가 다시 발생시에는 정상 표시됨.