[DW-VG4]All Sensor recording modes on web assembly issue with the channel alert icon.

Description

F/W: v1.5.3.2

Model: DW-VG49


This issue was first discovered with Motion + Sensor mode. I continued testing to discover all Sensor related recording schedules are affected.

RECORD > SCHEDULE - When the recording schedule is set to Motion + Sensor on all 4 channels CH1 does not display the sensor alert icon. The local side does display the alert, but on Chrome, it does not. CH 2,3,4 all does have the icon. CH4 the icon disappears after 2-3 mins. CH 2,3 remains on until the alarm is changed.

Please view the video link for reference (The sensor is set to NC to keep detection on): https://screenrec.com/share/0OP8IxqQVd

Additional information: With Sensor mode scheduled on all 4 Channels. Only CH1 does not display the icon. CH 2,3,4 the alert remains until the alarm is changed. Please view the screenshot for reference:

With Continous + Sensor mode scheduled on all 4 Channels. Only CH1 does not display the icon. CH 2,3,4 the alert remains until the alarm is changed. Please view the screenshot for reference:

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity