[BAY / DW-VG4] Network bandwidth too high

Description

Model: DW-VG416

FW: v1.5.4.3 / BAY 1.5.4.3

Local side


All camera models have been reset after

All 16CHs were online the warning alert was displayed.

  1. What can I do to resolve this issue?

  2. Is it possible to change the warning that is displayed to show which camera CH is the cause?

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity

Brandon Krebs 18 July 2024, 17:55

Improved 1.5.5.4

FOCUS_JH 5 June 2024, 02:46

최근 전달된 1.5.2.2 ver에서 재확인 부탁드립니다.

IVA Event 성능 개선 반영된 상태입니다.

FOCUS_JH 26 March 2024, 23:45

CPU 90%이상 과 Total 80Mbps 이상 2가지 모두 조건이 맞을때 팝업 뜨는 것은 9, 12, 16ch 모두 동일합니다.

>말씀하신 16ch 은 CPU가 90% 미만일 경우에만 160Mbps 제약이 성립이 됩니다.

일단 해당 SITE는 CPU 뿐 아니라 Memory 도 많이 올라간 상태에서 HDD Swap Momory 까지 사용중인 상태입니다.

그리고, IVA Event 활성화하지 않았다고 했는데.실제 확인시 거의 모든 CH 에서 IVA Event가 연속적으로 발생 하는것으로 확인됩니다.(26일 기준 4, 5, 7, 8, 9, 10, 11, 12, 13, 14, 16ch)

한번 올라간 Memory는 잘 내려가지 않으니 IVA Event를 사용하는 CH들을 줄이고, 리부팅 한뒤 모니터링 해봐야 할 것으로 보입니다.

참고로 다수의 TVT VA Event 와 C-PRO IVA Event 관련한 퍼포먼스 튜닝은 내부적으로 계속 진행해오고 있었습니다.

따라서 , 개선된 FW로 해당 SITE 에 적용해보고 어느정도 개선 여부를 판단할수 있을것 같습니다.

조만간 테스트용 FW 는 내부검토 끝나는대로 전달해 드리겠습니다.

David 26 March 2024, 15:41

답변 주신대로 CPU 사용률과 bandwidth 가 동시에 제한선을 넘을때인데,

아래 처음 리포트된 제품은 VmaxIP G4 16채널입니다. 이제품 아래 첫 화면 보시면,

CPU 99% 에 Bandwidth 73Mbps 입니다. 이제품은 160Mbps 가 제약으로 알고 있습니다.

그럼 현재 알람 발생이 안해야 정상인데, 알람이 발생해서 문의 드립니다.

확인 부탁드립니다.

Brandon Krebs 26 March 2024, 15:22

What is the average CPU usage per camera?

Below I mentioned a new site with no notifications or IVA event configured and the CPU is 99%

FOCUS_JH 26 March 2024, 00:56

NVR의 CPU 사용률 90% 이상 Total 80Mbps 이상의 2가지 조건이 동시에 발생했을 경우 뜨는 경고창은 모든 CH에 해당됩니다. CPU 90% 넘었거나 Total Bitrate 80Mbps 가 넘었다고 발생하지 않습니다.

2가지 요건이 함께 발생해야 경고 팝업창이 뜹니다.

David 26 March 2024, 00:24

현재 CPU가 99% 표시 되고 있는 제품은 VmaxIP G4 16채널 제품입니다.

이 제품은 160Mbps가 허용 Bandwidth 입니다. 메시지 자체도 잘못 된듯합니다.

또한 G4 12CH 제품 역시 CPU 99% 이지만 Bandwidth 알람은 없습니다. 이제품은 12채널이라서 허용 Bandwidth 80Mbps.

http://47.181.136.174:8080/cgi-bin/login.cgi

id: focus / pw: Admin1234!

Brandon Krebs 25 March 2024, 21:01

The installer that set this up has already requested and will receive a replacement. Can you check this system before it is exchanged?

So we have a new install the CPU stays at 99% the throughput was above 80Mbps with default settings.

IVA is not enabled on all cameras. There are no notifications set up on NVR.

I reduced all streams to the below screenshot. All cameras are directly connected to VMAX. There are 16 of the same model DWC-MVD8Wi28TW (4k). No matter what I did the CPU would not change. I had to reduce the throughput to below 80Mbps. To get the warning message to disappear. -----log file

  • What can be done to reduce the CPU usage to increase resolution?

P2P-1400882315D8-20450D
admin /  Admin/01

FOCUS_JH 13 September 2023, 07:47

CPU 사용율 영향 주는 요인은 여러 가지가 있지만

주요 요인은 아래와 같습니다. 아래 항목 하나하나 확인 필요합니다.

  1. Network 자원을 사용하는 기능(Email Notify, Mobile Push, Network Live & Playback등)

  2. VA Event 표시 기능

  3. Camera Stream bitrate 높게 설정되면서 HDD 상태에 따라 Write 에 부하가 걸리는 경우

Brandon Krebs 12 September 2023, 21:27

The warning continues to display.

All CHs are set up as suggested.

FOCUS_JH 12 September 2023, 02:55

NVR CPU 사용률은 여러요인으로 인해 올라가지만..DW 사용 환경기준으로 봤을때는 NVR 자체적으로 IVA Event 를 받아 화면에 OSD 하는 기능을 Off 하고, 카메라에서 설정된 OSD 영상으로만 사용하면 CPU 사용률은 내려 갈것입니다.

아래와 같이 NVR IVA EVENT 설정에서 USE 만 ON 하고 , 나머지 OSD는 모두 OFF 합니다.

Camera 의 Burnt-in Annotation 으로만 사용하면 CPU 사용율늘 낮추는데 도움될것입니다.

*NVR 과 Camera 의 IVA OSD 상관관계 및 시나리오.(참고)

> NVR의 IVA 설정은 Camera 쪽의 Burnt-in Annotation 과 별도 설정임.
Camera Burnt-in Annotation Off , NVR IVA 설정 ON => NVR자체적으로 Camera IVA Event 를 받아 NVR 영상화면에 OSD 출력.
  Camera Burnt-in Annotation On , NVR IVA 설정을 Off => Camera OSD를 NVR 영상화면에 보여줌.
만약 Camera 와 NVR 둘다 On 하게되면 2가지의 OSD 가 겹쳐서 OSD 가 두껍게 보여짐

Brandon Krebs 11 September 2023, 17:43

DW-VG416 How can I prevent two conditions from occurring simultaneously when all 16 POE ports are in use?

FOCUS_JH 11 September 2023, 08:30

HDD와는 무관하며,

NVR의 CPU 사용률 90% 이상 Total 80Mbps 이상의 2가지 조건이 동시에 발생했을 경우 경고창입니다. 단순히 Total Bitrate 80Mbps 가 넘었다고 발생하지 않습니다.

Brandon Krebs 7 September 2023, 22:23

Our spec. on the website is listed at 160 Mbps. is that incorrect?

Brandon Krebs 7 September 2023, 18:39

This recorder is using 2 hdds

Is this a common symptom when the HDD is full for 16CH?

I have not had this issue with 9CH or 12CH

FOCUS_JH 7 September 2023, 00:34

해당 이벤트는

Camera Total 트래픽이 80Mbps 이상이면서 NVR CPU 사용률이 90% 이상 일 때 발생하는 Event 입니다. 2가지 조건중 1가지만 해결해도 경고창 나오지 않습니다.