[DW-VA1G4] export set file (leave blank)

Description

VMAX A1 G4: 1.0.13.10

Smartwebviewer: Version 1.2.5.16


Summary: When exporting the configuration file, leaving the login field blank and pressing Enter allows the config file to be saved. However, if a myDW email is entered under PF Cloud Connection settings, the export operation is blocked and the file cannot be saved.

Attachments

Upload attachments

Drop your files to upload

(Max file size: 1.00 GiB)

Uploading...
(Template) Current File Name (1 / 7) 123KB / 2.1MB
(Template) File Name 123KB / 2.1MB
Upload completed. Click here to reload the page.

Child issues

Linked work items

Activity

Brandon Krebs 2 October 2025, 16:27

fixed 1.0.13.11

FOCUS_JH 1 October 2025, 08:48

v1.0.13.11_20251001 > 수정 확인됨.(NVR 과 동일한 시나리오 적용)

FOCUS_JH 29 September 2025, 04:16

제가 브라우저를 초기화후 확인해 보니 NVR 과 DVR 이 시나리오가 다른것 같습니다.

NVR은 별도 로그인 과정없이 MyDW CLoud 에서 Export Config 가 가능했고,

DVR은 별도 로그인 과정이 필요하며, DVR Local ID 와 Password를 입력해야 가능했습니다.

>단, 로그인창에서 4ch, 8ch은 로그인 계정입력없이 로그인 가능했고, 16ch 은 DVR Local ID , Password를 입력해야 가능했습니다.